IEC60529 Spray water test Nozzle, IPX56 water Jet Nozzle
1.IPX5: spray holes of 6.3 mm, can meet the 12.5 L/min (100 L/newspapers) + 0.625 L/min;
Test method: the center of water from the nozzle diameter at 2.5 m for 40 mm circle, specimen surface water every square metre shell time about 1 min, test specimen at least 3 min, The nozzle surface distance from shell specimen should be 2.5 ~ 3 m;
2.IPX6: spray holes of 12.5 mm, can meet the 100 L/min (6000 L/newspapers) + 5 L/min;
Test method: the center of water from the nozzle diameter at 2.5 m for 120 mm circle, specimen surface water every square metre shell time about 1 min, Test time: at least 3 min, The nozzle distance: the nozzle surface distance from shell specimen should be 2.5 ~ 3 m;